Refrigeration dryers are the first choice when it comes to reducing or removing moisture from compressed air. After passing through a refrigeration dryer, water in the compressed air will cool and condense. Dried air will then be discharged with the pressure dew point temperature reaching 2 to 10oC.

The Fusheng FR series refrigeration dryer provides both air-cooled models and water-cooled models. Each type can be further divided to high temperature and low temperature models based on the inlet air temperature demand from the customer end.

 

Uses ozone-friendly refrigerant R134a or R407C.

Uses anti-corrosive nickel-plated brass pipes for longer service life.

Uses a unique air heat exchanger with a brass pipe and fin design to prevent piping condensation.

Equipped with a computerized control panel and flow chart display for easiest operation.

Uses a flange connection for evaporators in power range from 300 hp and above to allow for easy maintenance.

You can check the interested models and send inquiry to us.
Model Size flow rate @ 7 kg/c㎡ (m³/min) Air inlet temp Refrigerant Power consumption (50/60Hz) kW Weight (kg)
1/2" 0.6 35°C R134a 0.3 / 0.4 18
3/4" 1.2 35°C R134a 0.4 / 0.5 28
1" 2.4 35°C R407C 0.4 / 0.5 37
1" 4.4 35°C R407C 0.8 / 0.9 43
1 1/2" 7 35°C R410A 1.3 / 1.5 70
1 1/2" 11 35°C R410A 1.5 / 1.8 81
2" 14 35°C R407C 2.0 / 2.2 114
2 1/2" 23.5 35°C R407C 3.4 / 4.1 175
1/2" 0.6 55°C R134a 0.4 / 0.5 19
3/4" 1.2 55°C R134a 0.4 / 0.5 28
1" 2.4 55°C R407C 0.8 / 0.9 43
1 1/2" 4.4 55°C R410A 1.3 / 1.5 70
1 1/2" 7 55°C R410A 1.5 / 1.8 81
2" 11 55°C R407C 3.4 / 2.6 114
2 1/2" 14 55°C R407C 3.4 / 4.1 175
OPEN
CLOSE
You can check the interested models and send inquiry to us.
Model Size flow rate @ 7 kg/c㎡ (m³/min) Air inlet temp Refrigerant Power consumption (50/60Hz) kW Weight (kg)
DN100 28.5 35°C R407C 5.0 / 6.1 500
DN100 34.2 35°C R407C 6.3 / 7.7 510
DN125 42.7 35°C R407C 7.6 / 9.3 800
DN125 52 35°C R407C 9.5 / 11.6 850
DN125 59.5 35°C R407C 9.9 / 12.1 900
DN150 70.8 35°C R407C 11.4 / 13.9 1000
DN125 79.3 35°C R407C 13 / 15.8 1100
DN80 21.4 50°C R407C 4.2 / 5.2 460
DN100 28.5 50°C R407C 5.5 / 6.8 590
DN100 34.2 50°C R407C 6.8 / 8.4 600
DN125 42.7 50°C R407C 8.2 / 10.1 900
DN125 59.5 50°C R407C 10.1 / 12.4 1000
DN150 70.8 50°C R407C 12.1 / 14.6 1200
OPEN
CLOSE
You can check the interested models and send inquiry to us.
Model Size flow rate @ 7 kg/c㎡ (m³/min) Air inlet temp Refrigerant Power consumption (50/60Hz) kW Weight (kg)
DN80 10.7 35°C R407C 2.1 / 2.5 260
DN80 14.4 35°C R407C 2.8 / 3.4 300
DN80 21.4 35°C R407C 2.8 / 3.4 350
DN100 28.5 35°C R407C 4.1 / 4.9 500
DN100 34.2 35°C R407C 5.3 / 6.4 550
DN125 42.7 35°C R407C 6.1 / 7.3 800
DN125 59.5 35°C R407C 7.8 / 9.4 900
DN150 70.8 35°C R407C 8.9 / 10.7 1000
DN150 79.3 35°C R407C 10.3 / 12.4 1100
DN200 106.2 35°C R407C 13.5 / 16.2 1400
DN200 141.4 35°C R407C 16.3 / 19.6 1600
DN200 169.7 35°C R407C 20.2 / 24.3 1800
DN250 212 35°C R407C 27.6 / 33.1 2400
DN300 282.7 35°C R407C 27.6 / 33.1 3000
DN400 340 35°C R407C 34.8 / 41.8 3500
DN400 425 35°C R407C 43.2 / 51.8 4000
OPEN
CLOSE
You can check the interested models and send inquiry to us.
Model Size flow rate @ 7 kg/c㎡ (m³/min) Air inlet temp Refrigerant Power consumption (50/60Hz) kW Weight (kg)
DN80 10.7 50°C R407C 2.1 / 2.5 340
DN80 14.4 50°C R407C 2.8 / 3.4 380
DN80 21.4 50°C R407C 2.8 / 3.4 450
DN100 28.5 50°C R407C 4.1 / 4.9 600
DN100 34.2 50°C R407C 5.3 / 6.4 650
DN125 42.7 50°C R407C 6.1 / 7.3 900
DN125 59.5 50°C R407C 7.8 / 9.4 1100
DN150 70.8 50°C R407C 8.9 / 10.7 1200
DN150 79.3 50°C R407C 10.3 / 12.4 1300
DN200 106.2 50°C R407C 13.5 / 16.2 1700
DN200 141.4 50°C R407C 16.3 / 19.6 1900
OPEN
CLOSE
You can check the interested models and send inquiry to us.
Model flow rate @ 7 kg/c㎡ (m³/min) Air inlet temp Refrigerant Power consumption (50/60Hz) kW Weight (kg)
1.35 35°C R134A 0.4/0.5 60
2.6 35°C R134A 0.7/0.9 80
3.6 35°C R417C 1.1/1.3 100
6.9 35°C R417C 1.4/1.7 114
10.7 35°C R407C 1.8/2.2 183
14.4 35°C R407C 2.3/2.8 240
17 50°C R407C 3.7/4.2 220
23 50°C R407C 4.7/5.3 270
26 50°C R407C 4.7/5.3 288
28 45°C R407C 4.7/5.3 288
30 45°C R407C 4.7/5.3 288
34 50°C R407C 8.8/9.0 300
OPEN
CLOSE
You can check the interested models and send inquiry to us.
Model flow rate @ 7 kg/c㎡ (m³/min) Air inlet temp Refrigerant Power consumption (50/60Hz) kW Weight (kg)
23 50 R407C 4.2 265
26 50 R407C 4.6/4.8 283
28 45 R407C 4.6/4.8 283
30 45 R407C 4.6/4.8 283
34 50 R407C 4.6/4.8 300
46 50 R407C 7.4/8.4 430
60 45 R407C 8.0/9.0 450
90 45 R407C 17/18 630
OPEN
CLOSE
Painting
General Factory
Online Chat

Product
Purchasing

After-Sales
Service

Select catalogue to download

Select catalogue to download
Verify code

Cookies:

We use cookies to optimize this website and continuously update it according to your needs. Please click on “Cookies” for detailed information on the use of cookies on this website. If you click “OK”, cookies will be activated. If you do not want cookies to be activated, you can opt out here . The settings can be changed at any time under “Cookies”.